LedState (ENUM) ¶ TYPE LedState : InOut: Name Initial STATIC_OFF 16#0 STATIC_GRN 16#1 STATIC_RED 16#2 STATIC_YLW 16#3 BLINK_GRN 16#10 BLINK_RED 16#11 BLINK_YLW 16#12 BLINK_GRN_RED 16#13 BLINK_GRN_YLW 16#14 BLINK_RED_YLW 16#15 BLINK_OFF_GRN 16#16 BLINK_OFF_RED 16#17 BLINK_OFF_YLW 16#18 BLINK_RED_GRN 16#19 BLINK_YLW_GRN 16#1A BLINK_YLW_RED 16#1B
Functions ¶ Log_EVENT_LogId (Function) SetLed (Function)
Library Reference ¶ This is a dictionary of all referenced libraries and their name spaces.
CmpPLCHandler Library Documentation ¶ Company 3S - Smart Software Solutions GmbH Title CmpPLCHandler Version 3.5.18.0 Categories System|SysLibs Namespace PLCH Author 3S - Smart Software Solutions GmbH Placeholder CmpPLCHandler Description 1 ¶ Library that allows access to the symbolic monitoring functionality of the PLCHandler Indices and tables ¶ 1 Based on CmpPLCHandler.library, last modified 01.04.2022, 08:14:11. LibDoc 4.4.0.0-b.27 The content file CmpPLCHandler.clean.json was generated with CODESYS V3.5 SP16 Patch 3 on 01.04.2022, 08:14:11.
Library Reference ¶ This is a dictionary of all referenced libraries and their name spaces. CmpPLCHandlerDataModelDefault ¶ Library Identification ¶ Placeholder: CmpPLCHandlerDataModel Default Resolution: CmpPLCHandlerDataModelDefault, * (CODESYS GmbH) Namespace: PLCH Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: CmpPLCHandlerDataModel SysTypes2 Interfaces ¶ Library Identification ¶ Name: SysTypes2 Interfaces Version: newest Company: System Namespace: SysTypes Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: SysTypes2 Interfaces, * (System)
File and Project Information ¶ Scope Name Type Content FileHeader creationDateTime date 01.04.2022, 08:14:11 companyName string 3S-Smart Software Solutions GmbH libraryFile CmpPLCHandler.library primaryProject True productName CODESYS productProfile CODESYS V3.5 SP16 Patch 3 contentFile CmpPLCHandler.clean.json version version 2.0.0.0 ProjectInformation IsEndUserLibrary bool False Released True LastModificationDateTime date 01.04.2022, 08:14:11 LibraryCategories library-category-list System|SysLibs Author string 3S - Smart Software Solutions GmbH Company 3S - Smart Software Solutions GmbH CompiledLibraryCompatibilityVersion CODESYS V3.5 SP15 DefaultNamespace PLCH Description See: Description DocFormat reStructuredText LanguageModelAttribute qualified-access-only Placeholder CmpPLCHandler Project CmpPLCHandler Title CmpPLCHandler Version version 3.5.18.0
CmpPLCHandlerDataModelDefault Library Documentation ¶ Company CODESYS GmbH Title CmpPLCHandlerDataModelDefault Version 3.5.18.0 Categories System|SysLibs Namespace PLCH Author CODESYS Development GmbH Placeholder CmpPLCHandlerDataModelDefault Description 1 ¶ Library that allows access to the symbolic monitoring functionality of the PLCHandler. This is an additional library needed by CmpPLCHandler.library in order to handle data access on all 32bit platforms and on Windows 64bit (LLP64 data model). Contents: ¶ CmpPLCHandler Structs Indices and tables ¶ 1 Based on CmpPLCHandlerDataModelDefault.library, last modified 01.04.2022, 08:14:28. LibDoc 4.4.0.0-b.27 The content file CmpPLCHandlerDataModelDefault.clean.json was generated with CODESYS V3.5 SP16 Patch 3 on 01.04.2022, 08:14:28.
Structs ¶ VariableValue (Struct)
CmpPLCHandler ¶ Structs VariableValue (Struct)
VariableValue (STRUCT) ¶ TYPE VariableValue : STRUCT Instances of this structure represent the value and status information for a single variable Note In fact this structure is the same than PlcVarValue from the PLCHandler SDK InOut: Name Type Comment ulTimeStamp UDINT UTC-Timestamp of the value, is read from the PLC Note The UTC-timestamp is not supported by all PLCs quality BYTE Quality of the value 1: Value was read from the PLC 0: Value was not read from the PLC data ARRAY [0..0] OF BYTE Array with the value. The concrete size of this array depends on the data type (byData[1] is only a placeholder with the minimum size). Should only be accessed, if bQuality is TRUE