IoDrvPLCNextAxio_Diag.ChildNodeCount (PROP) ¶ PROPERTY ChildNodeCount : CAA.COUNT Returns the number of childs below the current node
IoDrvPLCNextAxio_Diag.Connector (PROP) ¶ PROPERTY Connector : POINTER TO IoStandard.IoConfigConnector
IoDrvPLCNextAxio_Diag.Enable (PROP) ¶ PROPERTY Enable : BOOL This property returns if the node is enabled in the device tree. The setter can be used to change the Enabled flag. If enabling/disabling is not supported on the node the flag’s value will not change.
IoDrvPLCNextAxio_Diag.FirstChildNode (PROP) ¶ PROPERTY FirstChildNode : INode Returns the first child node below the current one
IoDrvPLCNextAxio_Diag.Index (PROP) ¶ PROPERTY Index : UDINT
IoDrvPLCNextAxio_Diag.IsRootNode (PROP) ¶ PROPERTY IsRootNode : BOOL returns true, if the current node is the root (plc) node, otherwise false
IoDrvPLCNextAxio_Diag.NextSiblingNode (PROP) ¶ PROPERTY NextSiblingNode : INode returns the next sibling node at the same level used for step through all nodes
IoDrvPLCNextAxio_Diag.ParentNode (PROP) ¶ PROPERTY ParentNode : INode Returns the parent node or zero if already the root node is reached
IoDrvPLCNextAxio_Diag.SiblingNodeCount (PROP) ¶ PROPERTY SiblingNodeCount : CAA.COUNT Returns the number of sibling (same level) nodes
IoDrvPfc200 Library Documentation ¶ Company : CODESYS Title : IoDrvPfc200 Version : 4.10.0.0 Categories : Intern|IoDrivers Namespace : IoDrvPfc200Lib Author : CODESYS Development Gm Placeholder : IoDrvPfc200 Description [ 1 ] ¶ Library for internal bus for PFC200 Contents: ¶ IoDrvPfc200 Function Blocks Library Information GetLibVersion (Function) GetLibVersionNumber (Function) IsLibReleased (Function) Indices and tables ¶ [ 1 ] Based on IoDrvPfc200.library, last modified 25.10.2023, 14:04:04. LibDoc 4.4.0.0-b.37 The content file IoDrvPfc200.clean.json was generated with CODESYS V3.5 SP16 Patch 3 on 25.10.2023, 14:04:06.